CR11108 — 11.6 x 10.8 mm, 3 V

What still fits this compartment, and what the voltage difference costs. Fit and voltage are separate answers.

CellFitVoltage Chemistry
SR44sits lower1.55 V -48.3%wrong classsilver oxide
SR43sits lower1.55 V -48.3%wrong classsilver oxide
SR42sits lower1.55 V -48.3%wrong classsilver oxide
SR54sits lower1.55 V -48.3%wrong classsilver oxide
SR55sits lower1.55 V -48.3%wrong classsilver oxide
LR44sits lower1.5 V -50.0%wrong classalkaline

Fit and voltage are separate answers here and they are never merged into one: fit is geometry, decided within 0.3 mm, and voltage is consequence, decided on the gap against the higher of the two nominal voltages. Neither of them answers chemistry. Rechargeable cells are never a drop-in for primary cells regardless of size; a zinc air cell begins discharging the moment its tab comes off; a device calibrated for a chemistry that holds its voltage flat will drift on one that sags. These are one manufacturer’s published nominal figures, so a cell that enters the compartment can still be the wrong cell, and a designation missing from them is missing from that catalog rather than from the world.

Source: batterycross.com · Energizer technical data, retrieved 1 September 2026