BATTERYCROSS Cell cross-reference, drawn to size

Index / No longer in the Energizer catalog

No longer in the Energizer catalog

133 designations no longer have a part in the Energizer catalog. The 125 listed here are the ones whose dimensions the maker publishes, which is what it takes to say anything about fit; the remaining 8 are in the code index. The table names the closest current cell, says in what sense it fits AND what the voltage difference costs — the two never answer each other. For 58 of them this catalog lists nothing of that size at all, which is a statement about the catalog and not about the world.

Fit answers whether it enters the compartment. Voltage answers whether the circuit will notice. A cell that fits is not always a safe substitute.

CellEnvelopeVoltsClosest currentFitWhat the swap costs
1.2H110.5 x 44.5 mm1.2 VHR03drop-in1.2 V 0%same volts
1.2H214.5 x 50.5 mm1.2 VHR6drop-in1.2 V 0%same volts
10F1515.1 x 15.9 x 34.9 mm15 Vnone in this catalog
10F2026.2 x 16.1 x 37 mm15 Vnone in this catalog
1140SO15.5 x 4.9 mm1.5 VEPX625Gtoo tall1.5 V 0%same volts
1157M8.9 x 3.3 mm1.4 Vnone in this catalog
1177SO11.6 x 1.6 mm1.55 VSR44too tall1.55 V 0%same volts
1313AP40.6 x 17 x 11.4 mm4.5 Vnone in this catalog
152F40110.3 x 68.3 x 106.4 mm225 Vnone in this catalog
15F1515.1 x 15.9 x 50.9 mm22.5 Vnone in this catalog
15F2026.2 x 16 x 51 mm22.5 Vnone in this catalog
160546 x 46 x 63 mm9 Vnone in this catalog
161119.1 x 50.8 mm9 Vnone in this catalog
1646.8 x 2.1 mm1.4 VSR60drop-in1.55 V +10.7%reads off
1937.9 x 5.4 mm1.5 VSR48drop-in1.55 V +3.3%close enough
20111.6 x 3.3 mm1.5 VLR54drop-in1.5 V 0%same volts
20F2026.2 x 16 x 65 mm30 Vnone in this catalog
21733.7 x 25 x 88.9 mm67.5 Vnone in this catalog
2CR1110812.8 x 25.2 mm6 V4LR44drop-in6 V 0%same volts
2LR5017.1 x 33.4 mm3 VCR17345too tall3 V 0%same volts
2LR5318.6 x 12.3 mmnot publishednone in this catalog
2MR916.9 x 15.4 mm3 Vnone in this catalog
3-03167.8 x 39.8 mm1.5 VA27sits lower12 V +700%wrong class
3-0316I8.2 x 39.8 mm1.5 VA27sits lower12 V +700%wrong class
3-041111.4 x 27.9 mm1.5 Vnone in this catalog
3-0411I11.8 x 28.1 mm1.5 VLR1too tall1.5 V 0%same volts
3-31210.3 x 42.8 mm1.5 V1811Asits lower12 V +700%wrong class
3-312I10.5 x 43.3 mm1.5 V1811Asits lower12 V +700%wrong class
3-31514 x 48 mm1.5 Vnone in this catalog
3-315I14.3 x 48.4 mm1.5 VLR6too tall1.5 V 0%same volts
3-315INNC14.3 x 47.6 mm1.5 VLR6too tall1.5 V 0%same volts
3-315IWC14.3 x 50.5 mm1.5 VLR6drop-in1.5 V 0%same volts
3-315WC14 x 50.5 mm1.5 Vnone in this catalog
3-33525.2 x 46.7 mm1.5 Vnone in this catalog
3-335I26.2 x 47.2 mm1.5 VLR14too tall1.5 V 0%same volts
3-335NNCI26.2 x 46.7 mm1.5 VLR14too tall1.5 V 0%same volts
3-335WC25.2 x 50 mm1.5 Vnone in this catalog
3-350I34.1 x 57.5 mm1.5 VLR20too tall1.5 V 0%same volts
3-350IWC34.1 x 61.1 mm1.5 VLR20too tall1.5 V 0%same volts
3-350NNCI34.1 x 57 mm1.5 VLR20too tall1.5 V 0%same volts
3-350WC33.2 x 61.5 mm1.5 Vnone in this catalog
3-361I32.9 x 87.8 mm1.5 Vnone in this catalog
30311.6 x 5.4 mm1.55 VSR44drop-in1.55 V 0%same volts
30F2026.6 x 16.1 x 92.5 mm45 Vnone in this catalog
30F4067.5 x 25.4 x 93.6 mm45 Vnone in this catalog
30R676.2 x 58.7 x 105 mm45 Vnone in this catalog
3336.8 x 1.1 mm1.55 VSR66too tall1.55 V 0%same volts
336F2076.2 x 41.2 x 142.9 mm510 Vnone in this catalog
3396.8 x 1.4 mm1.55 V321drop-in1.55 V 0%same volts
3617.9 x 2.1 mm1.55 VSR58drop-in1.55 V 0%same volts
36511.6 x 1.6 mm1.55 VSR44too tall1.55 V 0%same volts
3949.5 x 3.6 mm1.55 V394/380drop-in1.55 V 0%same volts
3LR20103.5 x 33.8 x 94 mm4.5 Vnone in this catalog
3LR5016.8 x 49.9 mm4.5 VCR17345sits lower3 V -33.3%wrong class
3MR5017 x 50 mm4.09 VCR17345sits lower3 V -26.7%wrong class
3MR916.8 x 21.5 mm4.5 VCR17345too tall3 V -33.3%wrong class
3R25100.1 x 33.3 x 101.6 mm4.5 Vnone in this catalog
41733.3 x 24.6 x 39.7 mm15 Vnone in this catalog
45F3071.4 x 35.4 x 63.5 mm67.5 Vnone in this catalog
45F4071.4 x 34.9 x 94.1 mm67.5 Vnone in this catalog
46048 x 34.9 x 61.1 mm45 Vnone in this catalog
4LR20-2141 x 118 x 67.5 mm6 Vnone in this catalog
4LR25Y68.2 x 68.2 x 112 mm6 V4LR25Xtoo tall6 V 0%same volts
4LR5017.1 x 66.6 mm6 VCR17345sits lower3 V -50.0%wrong class
4LR5217.1 x 44.9 mm6 VCR17345sits lower3 V -50.0%wrong class
4LR6135.6 x 9.2 x 48.5 mm6 Vnone in this catalog
4NR4315.2 x 20.5 mm6 Vnone in this catalog
4R25-2136.5 x 73 x 125.4 mm6 Vnone in this catalog
4R25-4219.1 x 71.4 x 163.5 mm6 Vnone in this catalog
4R25X68.2 x 68.2 x 115 mm6 V4LR25Xdrop-in6 V 0%same volts
4RN4312.7 x 20.5 mm6 V4LR44too tall6 V 0%same volts
4SR4413 x 25.2 mm6.2 V4LR44drop-in6 V -3.2%close enough
521136.5 x 73 x 127 mmnot publishednone in this catalog
5LR4412.7 x 27.7 mm7.5 V4LR44sits lower6 V -20.0%reads off
5LR5017.1 x 83.2 mm7.5 VCR17345sits lower3 V -60.0%wrong class
5LR5217.1 x 56.2 mm7.5 VCR17345sits lower3 V -60.0%wrong class
5R25-4184.2 x 103.2 x 163.5 mm7.5 Vnone in this catalog
60F4094.5 x 34.9 x 94.1 mm90 Vnone in this catalog
6F10065.1 x 51.6 x 80.2 mm9 Vnone in this catalog
6F22-955.5 x 29.4 x 158.8 mm9 Vnone in this catalog
6F2425.4 x 49.2 mm9 Vnone in this catalog
6F50-235.7 x 34.1 x 69.9 mm9 Vnone in this catalog
6LR5017.1 x 99.8 mm9 VCR17345sits lower3 V -66.7%wrong class
6R25-4217.9 x 103.2 x 163.5 mm9 Vnone in this catalog
71092.1 x 51.6 x 77.8 mm22.5 Vnone in this catalog
72268.3 x 56.4 x 99.2 mm300 Vnone in this catalog
7LR4413 x 47.2 mm10.5 V4LR44sits lower6 V -42.9%wrong class
8R25136 x 72.2 x 112.7 mm12 Vnone in this catalog
8R25-2219.1 x 71.4 x 163.5 mm12 Vnone in this catalog
8R25-5214.3 x 133.4 x 171.5 mm12 Vnone in this catalog
AC146X26.8 x 17 x 44.5 mm8.4 Vnone in this catalog
CR122512.5 x 2.5 mm3 VBR1225drop-in3 V 0%same volts
CR232023 x 2 mm3 Vnone in this catalog
E11A10.2 x 15.5 mm6 VE11AZdrop-in12 V +100%wrong class
E625G15.5 x 6.1 mm1.5 VEPX625Gdrop-in1.5 V 0%same volts
EPX82523 x 6.1 mm1.5 Vnone in this catalog
HS1419676.2 x 58.7 x 104.8 mmnot publishednone in this catalog
HS657188.9 x 53.2 x 77.8 mm22.5 Vnone in this catalog
LR4066.7 x 170 mm1.5 Vnone in this catalog
LR417.9 x 3.6 mm1.5 VSR41drop-in1.55 V +3.3%close enough
LR5015.8 x 16.5 mm1.5 VCR15H270too tall3 V +100%wrong class
LR5215.8 x 11.1 mm1.5 VEPX625Gsits lower1.5 V 0%same volts
LR5511.6 x 2.1 mm1.5 VSR55drop-in1.55 V +3.3%close enough
MR112 x 29 mm1.4 VLR1too tall1.5 V +7.1%reads off
MR417.9 x 3.7 mm1.4 VPR41drop-in1.45 V +3.6%close enough
MR4211.6 x 3.6 mm1.4 VSR42drop-in1.55 V +10.7%reads off
MR4311.6 x 4.2 mm1.4 VLR43drop-in1.5 V +7.1%reads off
MR4411.6 x 5.3 mm1.35 VPR44drop-in1.45 V +7.4%reads off
MR487.9 x 5.4 mm1.4 VPR48drop-in1.45 V +3.6%close enough
MR5016 x 16.5 mm1.4 Vnone in this catalog
MR5216 x 11.2 mm1.4 VCR1616sits lower3 V +114%wrong class
MR915.6 x 6 mm1.4 VEPX625Gdrop-in1.5 V +7.1%reads off
NR417.9 x 3.6 mm1.4 VPR41drop-in1.45 V +3.6%close enough
NR4311.6 x 4.2 mm1.4 VLR43drop-in1.5 V +7.1%reads off
NR4411.6 x 5.3 mm1.4 VPR44drop-in1.45 V +3.6%close enough
NR487.8 x 5.3 mm1.4 VPR48drop-in1.45 V +3.6%close enough
NR5216 x 11.2 mm1.4 VCR1616sits lower3 V +114%wrong class
NR614.2 x 50.5 mm1.5 VLR6drop-in1.5 V 0%same volts
PR4311.6 x 4.2 mm1.4 VLR43drop-in1.5 V +7.1%reads off
PR635.8 x 2.1 mm1.4 V1191SOdrop-in1.55 V +10.7%reads off
R25-266.7 x 33.8 x 102.4 mm1.5 Vnone in this catalog
R25-466.7 x 66.7 x 109.5 mm1.5 Vnone in this catalog
R4066.8 x 170.7 mm1.5 Vnone in this catalog
SR716W7.9 x 1.6 mm1.55 V341drop-in1.55 V 0%same volts
SR910SW9.5 x 1.1 mm1.55 V394/380too tall1.55 V 0%same volts

Before you swap anything

Everything here is computed from published dimensions and nominal voltages. That answers whether a cell enters the compartment and whether the voltage matches on paper. It does not answer what your device does with the difference, and it cannot: a cell that fits can still be the wrong cell.

One more limit, and it is the biggest. This site reads a single manufacturer’s catalog. When a page says a designation is not listed, that means Energizer no longer offers a part under it — not that nobody makes the cell. Other makers may still sell it, and for common sizes they usually do.

A voltage difference is one relation between two cells, and this page prints it from the cell it is about — in every table on the page, including the one listing cells no longer made. A figure always belongs to the cell whose voltage is printed beside it: a cell that runs lower than this one carries a minus here, one that runs higher carries a plus, and two cells at the same nominal voltage carry zero. Meet the same pair on the other cell’s page and the sign is the other one, with the figure taken against that cell instead of this one; where the two run at the same voltage, both pages print zero. The class beside the figure is not read off that figure directly. It is decided on the gap itself, taken against the higher of the two nominal voltages, so one pair of cells gets one class whichever page you meet it on: counted from this side the boundary of the class that still runs falls at 20.0% below and 25.0% above, which is the same gap divided once by the larger nominal and once by the smaller. What genuinely differs between the two directions is the consequence, and the words carry it: a cell that runs low makes a calibrated instrument read below true, and a cell that runs high makes it read above.

3 things this site cannot see. Whether the contacts reach a shorter cell. Whether the device was calibrated for a chemistry that holds its voltage flat, which silver oxide does and alkaline does not. Whether the equipment tolerates the higher current a different chemistry can deliver. Rechargeable cells are never a drop-in for primary cells regardless of size.